Postby gjenney2 » 13 Mar 2008, 20:59

thank you for your reply

So am I correct to assume that the TMC222 is not programmable, but takes commands and response to them?


Let me give you some background
I have placed an order for two PD-108-28 and have been working with TMCM110.

PD-108-28 it uses the TMC222 and has a micro controller. That sends commands to the TMC222? So I am able program PD-108-28 using TCML. Correct? Therefore, I'm able to access the temperature flags in the program?

[/img]
gjenney2
Power User
Power User
 
Posts: 15
Joined: 09 Mar 2008, 23:28
Location: Dayton-Oho

Postby Olav Kahlbaum (TRINAMIC) » 14 Mar 2008, 08:56

Yes, this is correct. The PD-108 uses a TMC222 and a microcontroller (which will be accessible via TMCL).
The TMC222 itself is pure hardware, it is not programmable (except some parameters like the address of the two wire interface that can be programmed into OTP memory).
User avatar
Olav Kahlbaum (TRINAMIC)
Site Admin
 
Posts: 3363
Joined: 11 Aug 2006, 08:02

PD-108-28

Postby Gavy » 04 Jun 2008, 14:27

Could we use TMCL-IDE control PD-108-28?If not how could we control it?
User avatar
Gavy
Power User
Power User
 
Posts: 97
Joined: 03 Aug 2007, 10:10

Postby Olav Kahlbaum (TRINAMIC) » 05 Jun 2008, 08:12

Yes, the latest TMCM-108 modules are shipped with a TCML firmware, so you can use the TMCL-IDE to control them.
User avatar
Olav Kahlbaum (TRINAMIC)
Site Admin
 
Posts: 3363
Joined: 11 Aug 2006, 08:02

Postby Gavy » 05 Jun 2008, 11:33

but we have PD-108-28 are older ,we could not control it with TMCL-IDE ,even conld not communication with it by RS485,Which way we can control it now?i cann,t find TMCM-108 file in your web or CD?
User avatar
Gavy
Power User
Power User
 
Posts: 97
Joined: 03 Aug 2007, 10:10

Postby Olav Kahlbaum (TRINAMIC) » 06 Jun 2008, 08:59

I do not know of any PD-108 that were not shipped with TMCL. We will put the latest TMCL firmware and the latest TMCL-IDE on the web today. Please download both and try to do a firmware update then (using the TMCL-IDE and a properly working RS485 interface (best for this purpose is our USB-2-RS485)).
User avatar
Olav Kahlbaum (TRINAMIC)
Site Admin
 
Posts: 3363
Joined: 11 Aug 2006, 08:02

Postby Gavy » 07 Jun 2008, 16:07

We had downloaded and built the new software ,but cann't communicate still.if we must use USB-2-RS485?
User avatar
Gavy
Power User
Power User
 
Posts: 97
Joined: 03 Aug 2007, 10:10

Postby Olav Kahlbaum (TRINAMIC) » 09 Jun 2008, 07:53

Yes, it would be best to do it with USB-2-RS485 (especially firmware dowloading)´.
When using other RS485 interfaces it might be necessary to set the "telegram puase time" to a value greater than 0 (try 20ms first and if this works you can go back in small steps). Please see the other threads about RS485 communication with TMCL.