ABOUT LED INDICATOR ON TMCM140-42-32

ABOUT LED INDICATOR ON TMCM140-42-32

Postby layman2008 » 29 Jun 2011, 17:42

DEAR SIR:
NOW I AM USING A TMCM140-42-232 CONTROL BOARD TO DRIVE A STEPMOTOR.THERE ARE TWO LED INDICATORS ON TMCM140-42-32,WOULD YOU LIKE TO TELL ME WHAT THE TWO LEDS INDICATE?THANKS.
layman2008
Power User
Power User
 
Posts: 16
Joined: 11 Apr 2011, 04:55

Re: ABOUT LED INDICATOR ON TMCM140-42-32

Postby Goeran Eggers (TRINAMIC) » 30 Jun 2011, 09:32

Both LEDs (red and green) on the board are controlled by the on-board processor / firmware. The functionality is dependent on the firmware actually used:

- TMCL: green LED: usually blinking slowly - indicating normal operation

- CANopen: behaviour of both LEDs according to CANopen standard (indicating state).
User avatar
Goeran Eggers (TRINAMIC)
Site Admin
 
Posts: 189
Joined: 18 Jul 2006, 15:28

Re: ABOUT LED INDICATOR ON TMCM140-42-32

Postby layman2008 » 30 Jun 2011, 11:24

HELLO ,WHAT DOES THE RED LED LIGHT INDICATE(IF THE RED LED IS LIGHTED )?THANKS.IS THERE A POWER LED ON TMCM140-42-32
layman2008
Power User
Power User
 
Posts: 16
Joined: 11 Apr 2011, 04:55

Re: ABOUT LED INDICATOR ON TMCM140-42-32

Postby Olav Kahlbaum (TRINAMIC) » 11 Jul 2011, 08:04

There is no power LED on the TMCM-140. The red LED on the TMCM-140 is not used with TMCL. It is only used in the CANopen firmware to indicate CAN bus errors. And in bootloader mode, both the green and the red LEDs are constantly on.
User avatar
Olav Kahlbaum (TRINAMIC)
Site Admin
 
Posts: 3363
Joined: 11 Aug 2006, 08:02


Return to Other topics on modules

Who is online

Users browsing this forum: No registered users and 1 guest